🏭 Functional Gear Manufacturer | Direct Purchase & Wholesale / OEM
WHOLESALE · OEM · PRIVATE LABEL

Peltier Cooling Vest Manufacturer for OEM & Wholesale

The Peltier Cooling Vest uses four removable thermoelectric modules to create active temperature differences between the cooling surface and the surrounding environment.

With three cooling levels, three heating levels, four large thermal-contact plates, adjustable buckle fitting, and removable electronics, the vest is designed for industrial work, field operations, outdoor activities, and OEM temperature-regulation projects.

MOQ: 10 Pcs Trial Orders

OEM & Private Label supported

Lead Time: By Quantity

Confirmed based on your order size

Flexible Logistics

Air, Sea & Door-to-Door available

Global Shipping

Transit times vary by chosen method

Direct Factory

Source Manufacturing

Product-Specific QC

Inspection Based on Product Requirements

OEM & ODM

Custom Solutions

Overview

As a Peltier Cooling Vest Manufacturer, ChaoYue Sports develops this model around a four-module thermoelectric system capable of both cooling and heating.

Unlike passive ice packs or fan-only garments, the Peltier system actively transfers heat through direct-contact thermal plates. Its cooling performance should therefore be understood as a temperature differential rather than a fixed final temperature.

For example, if the cooling surface operates approximately 16°C below the surrounding temperature, an ambient temperature of 35°C would correspond to a surface temperature of approximately 19°C. Actual performance varies according to ambient conditions, power supply, heat dissipation, wearing conditions, and selected operating level.

The current vest uses four removable semiconductor units, adjustable front buckles, and a polyester-spandex textile structure for industrial, outdoor, and general temperature-management applications.


Key Technical Features

Four Removable Peltier Modules

The vest is equipped with four semiconductor main units, each connected through a Type-C power cable.

The modules can be removed from the garment before cleaning.

Active Temperature-Difference Cooling

The Peltier system creates a temperature difference between the thermal-contact plate and the surrounding environment.

Cooling performance should therefore be described using temperature differential (ΔT) rather than claiming that the cooling surface will always reach one fixed temperature regardless of ambient conditions.

Under one internal test condition, an ambient temperature of approximately 28°C and a cooling-surface temperature of approximately 14°C represented a temperature difference of about 14°C.

This result applies to that test condition and should not be treated as a guaranteed differential under every environment.

Three Cooling and Three Heating Levels

The controller provides three selectable levels for each operating mode.

The operating manual identifies the controller references as:

Cooling mode

  • Level 1: 19°C reference
  • Level 2: 16°C reference
  • Level 3: 12°C reference

Heating mode

  • Level 1: 35°C reference
  • Level 2: 37°C reference
  • Level 3: 40°C reference

These values should be treated as controller reference levels, not guaranteed absolute surface temperatures under all ambient conditions.

5,625 mm² Thermal-Contact Plate per Main Unit

Each semiconductor main unit uses a 5,625 mm² thermal-contact plate, providing a relatively large direct-contact surface for heat transfer.

With four modules distributed across the vest, the system provides multiple localized temperature-control zones.

Per-Module Electrical Specification

According to the current operating manual, each semiconductor main unit is rated at:

  • Voltage: 5V
  • Current: 1A
  • Power: 5W

These values apply to one main unit, not to the complete four-module system as a single 5W device.

Adjustable Garment Structure

The current vest measures approximately:

  • Length: 50 cm
  • Shoulder width: 38 cm
  • Adjustable waist/chest range: 90–110 cm

The adjustable buckle structure allows the vest to be fitted over different clothing layers.

Removable Electronic Construction

The four semiconductor main units, controller wiring, power cables, and battery can be removed before washing.

This allows the textile vest to be cleaned separately from the electronic system.


Product Specifications

SpecificationDetails
Product NamePeltier Cooling Vest Manufacturer for OEM & Wholesale
Product TypeActive Cooling & Heating Vest
Temperature-Control TechnologyPeltier Thermoelectric
Semiconductor Main Units4
Cooling PrincipleActive temperature differential through direct-contact thermal plates
Thermal-Contact Area5,625 mm² per main unit
Cooling Control3 levels
Cooling Controller References19°C / 16°C / 12°C
Heating Control3 levels
Heating Controller References35°C / 37°C / 40°C
Per-Module Voltage5V
Per-Module Current1A
Per-Module Power5W
ConnectionType-C
Outer Material90% Polyester / 10% Spandex
Inner Material100% Polyester
Garment Length50 cm
Shoulder Width38 cm
Adjustable Fit Range90–110 cm
Product WeightApprox. 0.86 kg
Reference Power Bank20,000mAh
Reference RuntimeApprox. 280–360 minutes
CleaningGentle hand wash below 30°C after removing electronics

Technical specifications and dimensional details of the Peltier semiconductor cooling vest.


Applications

The Peltier Cooling Vest can be considered for:

  • Manufacturing facilities
  • Warehouses
  • Workshops
  • Outdoor construction
  • Logistics and delivery
  • Field maintenance
  • Outdoor occupational work
  • Motorcycling
  • Cycling
  • Fishing
  • Outdoor recreation
  • Low-temperature environments using heating mode

Potential B2B buyers include industrial-safety distributors, workwear suppliers, outdoor-equipment sellers, functional cooling brands, and OEM temperature-regulation product companies.

A diagonal split-screen product image showcasing the active cooling vest in outdoor sports scenarios. The left side shows a motorcycle rider leaning into a turn on a mountain road wearing the vest, and the right side shows a cyclist riding a road bike along a scenic lakeside road, demonstrating the vest's versatility.


OEM & Customization Options

This Peltier Cooling & Heating Vest supports OEM production from 500 pcs.

Available OEM options include:

  • Silkscreen logo printing
  • Embroidery
  • Leather patch branding
  • Custom retail packaging
  • Structural modifications
  • Functional modifications
  • Selected product configuration adjustments

The current quotation is based on the standard base vest configuration. Any structural or functional modification should be reviewed separately, and the final OEM cost will be confirmed after the requested adjustments are defined.


Product Comparison

Peltier Cooling Vest vs. Fan Vest vs. Ice-Pack Vest

FeaturePeltier Cooling & Heating VestFan VestIce-Pack Vest
Cooling PrincipleActive thermoelectric heat transferAmbient air circulationPassive cold storage
Direct Cooling SurfaceYesNoYes
Performance Depends on Ambient ConditionsYesYesYes
Adjustable Cooling3 levelsUsually airflow levelsNo active adjustment
Heating FunctionYesNoNo
Requires Electrical PowerYesYesNo
Requires Frozen MediaNoNoYes
Main Product DifferenceActive temperature differential + heatingAirflow-based coolingPassive stored cold

The Peltier system should not be described as maintaining one fixed surface temperature in every environment. Its main functional difference is the ability to actively create a temperature difference relative to surrounding conditions.


Ordering & Production Information

The standard base vest is available for evaluation samples and trial orders, while OEM projects begin from 500 pcs.

Current ordering information:

  • Evaluation Sample: 1 pc
  • Standard Trial Orders: 50 / 100 / 200 pcs
  • OEM Production: 500 pcs and above
  • Standard Packaging: 10 pcs/carton, with individual English color boxes
  • Carton Size: 59.5 × 35.5 × 37.5 cm
  • Carton Weight: Net 10.5 kg / Gross 11.6 kg
  • Delivery Term: FOB Shenzhen, including inland transport and customs clearance
  • Power Bank: Excluded from the standard vest configuration and quoted separately if required

For evaluation orders, vest-only sample shipping is quoted according to the final destination. If the project proceeds, the sample product cost can be credited against the first trial or mass-production order. Battery shipping is quoted separately because lithium batteries require dedicated transportation arrangements.


Usage Limitations & Care

  • Disconnect the four Type-C cables before cleaning.
  • Remove all semiconductor main units from the vest.
  • Remove the controller power cable.
  • Remove the battery and other electrical components.
  • Hand wash gently below 30°C.
  • Do not wash the electronic modules.
  • Do not operate damaged electrical components.
  • Keep the battery and electronic system away from water.
  • Do not submerge the powered product.
  • Do not use in highly explosive environments.
  • Cooling performance varies with ambient temperature, heat dissipation, power supply, airflow, garment fit, and operating level.
  • Do not describe controller reference values as guaranteed cooling-surface temperatures in every environment.

FAQ

1. Does the Peltier Cooling Vest always cool to 12°C, 16°C, or 19°C?

No.

Those values are the three cooling references shown on the current controller and operating manual, but actual cooling-surface temperature depends on environmental and operating conditions.

The Peltier system works by generating a temperature difference. For example, if an approximately 14°C differential is achieved under a particular condition, a 35°C ambient environment would correspond to approximately 21°C at the cooling surface. That same differential should not automatically be assumed under every environment.

2. What cooling performance has ChaoYue actually measured?

Under one current internal thermal-imaging test condition, the ambient temperature was approximately 28°C and the cooling surface measured approximately 14°C.

That represents a temperature difference of roughly 14°C under that specific test condition.

We therefore present the result together with its test environment rather than claiming that the vest always reaches 14°C.

3. How many Peltier modules are used, and what is the electrical specification?

The vest uses four removable semiconductor main units.

According to the current operating manual, each individual main unit is rated at 5V, 1A, and 5W, and each connects through a Type-C cable.

Each main unit also uses a 5,625 mm² thermal-contact plate.

4. What runtime can buyers expect?

The operating manual lists approximately 280–360 minutes using a 20,000mAh power bank as the reference configuration.

Actual runtime can vary depending on operating mode, selected level, power-bank condition, environmental temperature, and other operating conditions.

5. How should the vest be cleaned and maintained?

All electronic components must be removed before washing, including the four semiconductor main units, Type-C connections, controller cable, and power source.

The textile vest should then be gently hand washed below 30°C. The semiconductor modules and electrical components must not be washed or submerged.

0
    0
    Your Cart
    Your cart is empty
    Have a Question? Leave Us a Message!

    Contact Us

    Send us your product requirements for sports supports or orthopedic braces. Our team will review your inquiry and respond by email.